Bureau of Energy Efficiency (Particulars and Manner of their Display on Labels of Distribution Transformers) Regulations, 2009
Text
The 6caette of ',3ndia EXTRAORDINARY WTI Ill VIM 4 PART HI—Section 4 Richit 14c6ifOt PUBLISHED BY AUTHORITY lt 114] No.. 114] NEW DELHI, TUESDAY, JULY 7, 2009/ASADHA 16, 1931 2478 G1/2009 ( 1) [PART III-SEC. 4] ljft-u Orruff afrrdr 4; e)c1 E (f) 4mm 5mm 4mm 11 5m m Total Losses at : 50% loading - 520 Watts 100% loading - 1800 Watts Equipment : Distribution Transformer Type : Oil filled naturally cooled Make : )00( Model / Year : " Capacity : 100kVA,. 2mm. 3mm E 3mm v.) Under test conditions, whstn *tad in accordant* '1th IS 1160:1.89 12mm E to 5mm Piqif 3(2) eftrq) fdk-Nur - 1,4-14314 44(41- Gzin — 63mm 60mm 29mm E E E to 1 Om m Black Outline (Outer) .5pt Black Outline Inner) 1 5pt Yellow Y:40 Red — Star Outline Black K:30 Yellow Y:40 7.5 •t text Black ( Anal Black) Black 15 • t text white Yellow Y:20 • Outline 1pt Black text 6pt (Anal Bold) Total Losses a 50% loading - 520 Watts 100% loading - 1800 Watts Equipment : Distribution Transformer Type : Oil filled naturally cooled Make : XXX • Model / Year : Red 9 it White text (Anal Bold) Black text 8.5pt (Anal Black) Capacity : 100kVA DEW IS LEE IMP C4 NRIVE Under test conditions, when tested with IS 1180:1989 in accordance • THE GAZE 11'E OF INDIA : EXTRAORDINARY [PART III--SEC. 4] 61 TIT CP - #363797 X15 — #00AA56 Total Losses at : 50% loading - 520 Watts 100% loading - 1800 Watts Equipment : Distribution Transformer Type : Oil filled naturally cooled Make : XXX Wile! / Year : Capacity : 100kVA Under test conditions, when tested in accordance with IS 1110:1915 [f4T719.-111/4/185/09-3W1.] THE BUREAU OF ENERGY EFFICIENCY NOTIFICATION New Delhi, the 6th July, 2009 No. 2/11(5)103-BEE.-3.--Whereas the draft regulations namely, the Bureau of Energy Efficiency (Particulars and Manner of their Display on Labels of Distribution Transformers) Regulations, 2009, were published vide notification number 2/11(5)/03-BEE.-3, dated 12th January, 2009,in the Gazette of India, Extraordinary, Part III, Section 4, dated the 12th January 2009, as required under sub-section (1) of section 58 of the Energy Conservation Act, 2001 (52 of 2001), inviting objections or suggestions from persons likely to be affected thereby within the specified period of forty-five days from the date of publication of the said notification in the Official Gazette; And whereas copies of the said draft regulations were made available to the public on the 12th January, 2009; And whereas suggestions have been received with respect to the said draft regulations within the specified period aforesaid; And whereas the suggestions received in this regard have been taken into consideration; Now, therefore, in exercise of the powers conferred by clause (i) of sub- section (2) of section 58 read with clause(d) of section 14 of the said Act, the Bureau, with the previous approval of the Central Government, hereby makes the following regulations, namely:- 1. Short title and commencement.- (1) These regulations may be called the Bureau of Energy Efficiency (Particulars and Manner of their Display on Labels of Distribution Transformers) Regulations, 2009. (2) They shall come into force on the date of their publication in the Official Gazette. 2. Definition. — (1) In these regulations, unless the context otherwise requires,- (a) "Act" means the Energy Conservation Act, 2001; (b) "distribution transformer" means the transformer which is oil immersed, naturally air cooled, three phased, double wound, non- sealed ,out door distribution transformer of standgrd ratings of 16, 25, 63, 100, 160 and 200 kVA of 11 kV which is manufactured or commercially purchased or sold in India; (c) "label" means any written, printed, marked, stamped or graphic matter affixed to, or appearing upon, the distribution transformer; (d) "section" means the section of the Act; (e) "star rating or star level" means the level of energy efficiency displayed on the label of distribution transformer on the basis of relative energy efficiencies or loss standards which is the total losses at fifty percent. loading and hundred percent. loading of the distribution transformer. (2) Words and expressions used herein and not defined, but defined in the Act, shall have the meanings respectively assigned to them in the Act. 3. Particulars to be displayed on the labels.- (1) On every distribution transformer the following particulars shall be displayed on its label, namely:- (a) the Logo of the Bureau of Energy Efficiency; (b) that the equipment is a distribution transformer; (c) that it is a oil filled, naturally cooled type; (d) name of the manufacturer and brand; (e) capacity in kVA as tested; (f) voltage is upto 11kV; (g) total losses at 50% loading in watts; (h) total losses at 100% loading in watts; (i) star level; (j) model and year of manufacturing: (k) Bureau's authorisation number. (2) The design, colour, size and content of label shall be as specified in the Schedule annexed to these regulations. 4. Time limit for display of Labels.- A label containing particulars specified in regulation 3 shall be displayed on every distribution transformer within a period of six months from the date of coming into force of these regulations. 5. Manner of display of label.- The label shall be affixed on the front base of the distribution transformer near the name plate, so as to be prominently visible. ,2to8 -1-1e)(3) ti 10mm E E T-; 30mm E E 63mm 60mm 29mm MORE STARS MORE SAVINGS POWER SAVINGS GUIDE 7mm E E Total Losses at : 50% loading - 520 Watts 100% loading - 1800 Watts Equipment : Distribution Transformer Type : Oil filled naturally cooled Make : XXX Model / Year Capacity : 1001(VA 2 TOT 4 4mm E Smm 1-- 4mm 4 2mm 3rf E 12mm V"' Under test conditions. when *led M secordeerce wills IS 111101,111 43mm 4 10 n1C1 ; E r. Schedule [See regulation 3(2)] Details of particulars to be displayed on labels of Distribution Transformer. (1) Label design, size, colour scheme and content of the label shall include:- (i) the following dimensional design of label, namely:- ....amo6••••■••• Black Outline (Outer) .5pt Yellow Y:40 . Red Yellow Y:40 T.5•1 text Black ( Arial Black) Black 15 text white Outline "Ipt 50% loading - 520 Watts 100% loading • 1800 Watts (ii) the following colour scheme for the label, namely:- Black text 6pt 'Anal Bolcil Equipment : Distribution Transformer Type : Oil Idled naturally cooled Maim : XXX -*Model / Year : Capacity : 100kVA Outline 5p1 Black 5pt text (Arial Narrow) • Untie. las' conditions, wino knied I, sonortlence with IS 11 WINN (iii) the following colour scheme for Bureau's logo, namely:- BLUE — Luminance or lightness(L) :28, chromatic components -a:24 b:54 Web colour code - #363797 GREEN — Luminance or lightness(L) :61, chromatic components -a:-53 b:32 Web colour code - #00AA56; i"11 Total Losses at : 50% loading - 520 Watts 100% loading - 1800 Watts (iv) the following complete specimen of a printed label for distribution transformer, namely:- Typo : Oil Glad smarally Naiad Yak• : UDC Model / Thar : Capacity : 100SVA Under teal confiner's, when levied in aceeteeeee with IS 11110:111111 (2) Material of the label shall be of non-detachable weather proof type. AJAY MATHUR, Director General Printed by the Manager, Govt. of India Press, Ring Road, Mayapuri, .Nca Delhi-110064 and Published by the Controller of Publications, Delhi-110054. Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12